Installation [09/2014 - ]: Procedure
- INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
HINT:
Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [09/2014 - ]
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.NOTE:
- If the mass air flow meter sub-assembly has been struck or dropped, replace it.
- If reusing the mass air flow meter sub-assembly, be sure to inspect the O-ring.
- Make sure that the O-ring is not cracked or does not move out of place during installation.
- Install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.
- INSTALL AIR CLEANER CAP WITH AIR CLEANER HOSE
- CONNECT VENTILATION HOSE
- INSTALL V-BANK COVER SUB-ASSEMBLY
Refer to PROCEDURE - Step 96 [09/2014 - 05/2018] , or refer to PROCEDURE - Step 97 [05/2018 - 03/2019] , or refer to PROCEDURE - Step 96 [03/2019 - ]
- PERFORM INITIALIZATION
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.
Refer to INITIALIZATION [09/2014 - ]
- Perform "Inspection After Repair" after replacing the mass air flow meter sub-assembly.