1979 RX7
Remove air filter from anti-afterburn valve solenoid and connect a tube to nipple as shown. See Figure. Disconnect vacuum tube from solenoid valve. Blow through tube. Air should come out opposite port of solenoid. Disconnect relief solenoid valve. Connect battery power to terminals on valve. Blow through tube again. Air should come out of side port.