Timer Test (GLC Only)
- To check timer (located under instrument panel on left side panel), connect wires to terminals "A", "B", and "C" of timer. See Fig 1. Connect a wire with a 30, 000 ohm resistor to terminal "D". Connect a wire with a 3.4 watt test lamp to terminal "E". Connect a voltmeter to terminal "D" and to negative battery terminal.
- Connect wires from terminals "A", "D", and "E" to battery positive terminal. Connect wire from terminal "C" to battery negative terminal. Voltmeter should show more than 6 volts.
Courtesy of NOT AVAILABLE
- Then, connect wire from terminal "B" to battery positive terminal. Instantly, voltmeter should show less than 1 volt and test lamp should light. After approximately 105-135 seconds from showing 1 volt, voltmeter should indicate 8 volts. If not, replace timer.