Water THERMO Valve
- Remove water thermo valve and connect a piece of tubing to each nipple. Immerse valve in container of water. Insert thermometer and slowly heat water.
- At temperature of 122°F (50°C) or above, blow into one of the hoses. Air should pass through valve. If not, replace water thermo valve.