Intake Shutter Valve System
Connect a vacuum gauge to intake manifold vacuum. Start engine and run at idle. Disconnect coupler at 3-way solenoid valve. Vacuum gauge should read 17 in. Hg. If not, turn adjusting screw on intake shutter valve until vacuum reads 17 in. Hg at 700 RPM.