Airflow Measuring Plate Test
Using a screwdriver, depress measuring plate fully and measure resistance between terminals on airflow meter connector. See AIRFLOW MEASURING PLATE RESISTANCE table for resistance values.
AIRFLOW MEASURING PLATE RESISTANCE
| Terminals | Ohms | |
|---|---|---|
| E1 to FC | ||
| Plate Fully Closed | No Continuity | |
| Plate Fully Open | 0 | |
| E2 to VS | ||
| Plate Fully Closed | 20-400 | |
| Plate Fully Open | 20-1000 | |