Atmospheric Pressure Sensor
Connect voltmeter to terminal "D" of atmospheric pressure sensor. Turn ignition on and take voltage reading. See ATMOSPHERIC PRESSURE SENSOR table.
ATMOSPHERIC PRESSURE SENSOR SPECIFICATIONS
| Altitude (Feet) | Voltage |
|---|---|
| Sea Level | 3.5-4.5 |
| 6500 | 2.5-3.5 |