Power Cut Switch Test
Check continuity across specified terminals of main switch connector with power cut switch (on/off switch) button held in specified position. See POWER CUT SWITCH CONTINUITY TEST TEST table. See Figure . Replace main switch if continuity is not as specified.
POWER CUT SWITCH CONTINUITY TEST
| Switch Position | Terminals | Continuity |
|---|---|---|
| ON | H & G | Yes |
| OFF | H & G | No |