Airflow Meter/Sensor Inspection
Inspect airflow meter for damage and ensure measuring plate moves smoothly. See Fig 1
. Disconnect airflow meter connector. Move measuring plate and measure resistance between terminals. See AIRFLOW METER TERMINAL RESISTANCE
table.
AIRFLOW SENSOR TERMINAL VOLTAGES
| Terminal Wire Color |
Volts - Ignition ON |
Volts - Engine Running |
| Black/Yellow (Power Supply) |
12 |
12 |
| Green/Orange (Burn-Off) |
0 |
0 |
| Green/Black (Airflow Mass) |
1.0-2.0 |
1.9-5.0 |
| Green/Yellow (Ground) |
About 0 |
About 0 |
| Black/Orange (Ground) |
About 0 |
About 0 |
AIRFLOW METER TERMINAL RESISTANCE
| Terminals |
Ohms - Fully Closed |
Ohms - Fully Open |
| E2-Vs |
100-400 |
20-1000 |
| E2-Vc |
100-400 |
100-400 |
| E2-Vb |
200-400 |
200-400 |
| E2-THA |
13,600-18,400 |
13,600-18,400 |
|
2200-2700 |
2200-2700 |
|
500-700 |
500-700 |
| E1-Fc |
Infinite |
0 |
Courtesy of MAZDA MOTORS CORP.