Air Induction Systems (Turbocharger): WASTEGATE
- Engine must be cool. Remove exhaust manifold insulator and side insulator. Remove hose connected to actuator and connect compressed air source with pressure gauge. See Fig 1 .
- Apply 10 psi (0.7 kg/cm2 ) of compressed air to actuator. Verify actuator rod moves when connecting and disconnecting hose supplying compressed air.
CAUTION:
DO NOT apply compressed air more than 14 psi (1.0 kg/cm2
).