Power Circuits
Using a voltmeter, check for battery voltage between ECA terminal No. 1 (constant battery power) and ground. Check for battery voltage at terminals No. 37 and 57 with ignition on. If battery voltage is not present, power is not being supplied from EEC power relay. See CIRCUIT TEST B in TESTS W/CODES - NAVAJO article.