Sub-Switch Test
Check continuity across specified terminals of sub-switch connector with switch button held in specified position. See SUB-SWITCH CONTINUITY TEST table. See Fig 1 . Replace sub-switch if continuity is not as specified.
SUB-SWITCH CONTINUITY TEST
| Application & Switch Position | Terminals |
|---|---|
| UP | A & E; B & D |
| Off (Neutral) | A & E; D & F |
| DOWN | B & E; D & F |