Engine Controls - Sensor Operating Range Charts: Introduction
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
AIR CHARGE TEMPERATURE (ACT) SENSOR RESISTANCE
| Temperature | Ohms |
|---|---|
| 50°F (10°C) | 58,750 |
| 68°F (20°C) | 37,300 |
| 176°F (80°C) | 384 |
| 194°F (90°C) | 280 |
ECT SENSOR RESISTANCE
| Temperature | Ohms |
|---|---|
| 50°F (10°C) | 58,750 |
| 68°F (20°C) | 37,300 |
| 176°F (80°C) | 384 |
| 194°F (90°C) | 280 |
OXYGEN SENSOR
| Operating Condition | Voltage |
|---|---|
| Rapidly Accelerating | 0.5-1.0 |
| Deceleration | 0.0-0.4 |
TP SENSOR VOLTAGE
| Application | (1) Voltage | ||
|---|---|---|---|
| Closed Throttle | .60 | ||
| Wide Open Throttle | 4.50 | ||
|
|||