LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 1994 >> B2300 SE, Automatic >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Engine Controls - Sensor Operating Range Charts >> Introduction
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Engine Controls - Sensor Operating Range Charts: Introduction

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

NOTE: Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
AIR CHARGE TEMPERATURE (ACT) SENSOR RESISTANCE

Temperature Ohms
50°F (10°C) 58,750
68°F (20°C) 37,300
176°F (80°C) 384
194°F (90°C) 280
ECT SENSOR RESISTANCE

Temperature Ohms
50°F (10°C) 58,750
68°F (20°C) 37,300
176°F (80°C) 384
194°F (90°C) 280
OXYGEN SENSOR

Operating Condition Voltage
Rapidly Accelerating 0.5-1.0
Deceleration 0.0-0.4
TP SENSOR VOLTAGE

Application (1) Voltage
Closed Throttle .60
Wide Open Throttle 4.50
(1) Check voltage with voltmeter connected between Breakout Box Pin Nos. 46 and 47.