Ignition Checks: IGNITOR
- Turn ignition off. Disconnect ignitor connector and install Test Harness (49 H018 001). Using a needle-type ohmmeter, connect (+) lead to ground and (-) lead to single-pin test wire of test harness. See Fig 1
.CAUTION: Ensure ohmmeter is installed with (+) lead to ground and (-) lead to single-pin wire of test harness. DO NOT reverse leads or damage may result.
- Connect Ignitor Checker (49 F018 002) to other lead of test harness and to battery. Set ohmmeter to X1 scale.
- Turn ignition on. DO NOT touch ignitor checker SW1 switch. Push up ignitor checker SW2 switch and note ohmmeter reading. Ohmmeter needle should jump to 1/2 of the scale and then return. If ohmmeter does not operate as specified, replace ignitor.