Engine Controls - Sensor Operating Range Charts: Introduction
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
AIRFLOW MTR TERM RESISTANCE
| Terminals |
Fully Closed Ohms |
Fully Open Ohms |
| E2 & Vs |
200-600 |
20-1000 |
| E2 & Vc |
200-400 |
200-400 |
| E2 & THA |
| -4°F (-20°C) |
13,600-18,400 |
13,600-18,400 |
| 68°F (20°C) |
2210-2690 |
2100-2690 |
| 140°F (60°C) |
493-667 |
493-667 |
| E1 & Fc |
Infinite |
0 |
OXYGEN SENSOR
| Operating Condition |
Voltage |
| Rapidly Accelerating |
0.5-1.0 |
| Deceleration |
0.0-0.4 |
TP SENSOR CONTINUITY
| Test Condition |
Continuity |
| .004" (.10 mm) |
Yes |
| .024" (.60 mm) |
No |
TP SENSOR CONTINUITY
| Test Condition |
Continuity Between IDL & TL/E |
Continuity Between POW & TL/E |
| .016" (.41 mm) |
Yes |
No |
| .027" (.7 mm) |
No |
No |
| WOT |
No |
Yes |