Main Switch
Check continuity across specified terminals of main switch connector with main switch button held in specified position. See appropriate MAIN SWITCH CONTINUITY TEST table. SeeFig 1 and Fig 2 . Replace main switch if continuity is not as specified.
MAIN SWITCH CONTINUITY TEST
| Switch Position (1) | Terminals | |||
|---|---|---|---|---|
| Driver | ||||
| UP | A & C; B & J | |||
| DOWN | A & J; B & C | |||
| One-Touch DOWN | A & J; B & C | |||
| Off (Neutral) | A, B & C | |||
| Passenger | ||||
| UP | C & I; H & J | |||
| DOWN | C & H; I & J | |||
| Off (Neutral) | C, H & I | |||
|
||||