Throttle Position (TP) Sensor
NOTE:
For information on connector terminal identification and test conditions specified in the following tables, see ADJUSTMENTS
article.
TP SENSOR CONTINUITY
| Condition (1) | Continuity Between Terminals "A" & "B" | ||
|---|---|---|---|
| .012" (.30 mm) | Yes | ||
| .016" (.40 mm) | No | ||
|
|||
TP SENSOR VOLTAGE
| Wire Color To ground | Closed Throttle Volts | WOT Volts | ||
|---|---|---|---|---|
| Blue/White (2M) (1) | 0.1-1.0 | 2.8-4.5 | ||
|
||||