Component Testing: Sub-Switch
Check continuity across specified terminals of sub-switch connector with main switch button held in position. SeeFig 1 . See SUB-SWITCH CONTINUITY TEST . Replace sub-switch if continuity is not as specified.
SUB-SWITCH CONTINUITY TEST
| Switch Position | Terminals |
|---|---|
| UP | D & H; B & G |
| Off (Neutral) | A & B; D & H |
| DOWN | A & B; G & H |