Ignition Control Module
- Turn ignition off. Disconnect Ignition Control Module (ICM) connector and install Test Harness (49 H018 910). Using a analog volt/ohmmeter, connect (+) lead to ground and (-) lead to single-pin test wire of test harness. See Fig 1
.CAUTION: Ensure ohmmeter is installed with (+) lead to ground and (-) lead to single-pin wire of test harness. DO NOT reverse leads, or damage may result.
- Connect Ignitor Checker (49 F018 002) to other lead of test harness and to battery. Set ohmmeter to X1 scale.
- Turn ignition on. DO NOT touch ignitor checker switch SW1. Push up ignitor checker switch SW2 and note ohmmeter reading. Ohmmeter needle should jump to 1/2 of the scale and then return. If ohmmeter does not operate as specified, replace ICM.