Test No. 1
- Turn ignition on. Check 30-amp power window fuse in joint box, near left kick panel. If fuse is blown, replace fuse (repair wiring if necessary). If fuse is okay, go to next step.
- Measure voltage at Black/Red wire terminal of main switch connector. If battery voltage does not exist, repair Black/Red wire between joint box and main switch. If battery voltage exists, go to next step.
- Disconnect main switch connector. Check continuity between ground and Black wire terminal of main switch connector. If continuity does not exist, repair Black wire between ground and main switch. If continuity exists, check main switch. See MAIN SWITCH TEST under COMPONENT TESTS.