Shutter Valve Actuators
Disconnect vacuum hose from shutter valve actuators No. 1 and 2. See Figure . Connect vacuum pump to actuator. Apply vacuum to each actuator separately and verify shutter valve rod retracts. Ensure both shutter valves move freely. Replace actuator as necessary.