When Customer Has Two Or More Valid Keys

Fig 1: Illustration Of Keys
G01196505
NOTE:
  • If no specific time interval is given, each step should be performed within 30 seconds of the previous step.
  1. Cut new transponder equipped key(s) if necessary.
  2. Replace PCM. See PCM  .
  3. Using key 1, turn ignition switch to ON position, and observe that security light illuminates (for 1-2 seconds  ) in instrument cluster.
    1. Turn key 1 to LOCK position.
    2. Turn key 1 to ON position then back to LOCK position six times  . The key should not remain at ON position or LOCK position for more than 1 second  . It is particularly important to ensure that the 6th turn is done within 1 second. 
    3. Remove key 1.
  4. Using key 2, turn ignition switch to ON position. Observe that security light illuminates (for 1-2 seconds  ).
    1. Turn key 2 to LOCK position and remove from steering lock.
  5. Using key 1, start engine. Observe that security light illuminates (for 1-2 seconds  ) and engine continues to run.
    1. Turn key 1 to LOCK position and remove from steering lock.
  6. Repeat Step  5 with key 3.
  7. If there are 4-8 keys (valid and/or new keys), repeat Step  5 .
  8. Wait for 30 seconds  to quit reprogram mode.
  9. After reprogramming, clear DTCs of PCM with WDS or equivalent.