When Customer Has Two Or More Valid Keys
NOTE:
- If no specific time interval is given, each step should be performed within 30 seconds of the previous step.
- Cut new transponder equipped key(s) if necessary.
- Replace PCM. See PCM .
- Using key 1, turn ignition switch to ON position, and observe that security light illuminates (for 1-2 seconds
) in instrument cluster.
- Turn key 1 to LOCK position.
- Turn key 1 to ON position then back to LOCK position six times . The key should not remain at ON position or LOCK position for more than 1 second . It is particularly important to ensure that the 6th turn is done within 1 second.
- Remove key 1.
- Using key 2, turn ignition switch to ON position. Observe that security light illuminates (for 1-2 seconds
).
- Turn key 2 to LOCK position and remove from steering lock.
- Using key 1, start engine. Observe that security light illuminates (for 1-2 seconds
) and engine continues to run.
- Turn key 1 to LOCK position and remove from steering lock.
- Repeat Step 5 with key 3.
- If there are 4-8 keys (valid and/or new keys), repeat Step 5 .
- Wait for 30 seconds to quit reprogram mode.
- After reprogramming, clear DTCs of PCM with WDS or equivalent.