DTC P1602: Immobilizer To Pcm Communication Error: Condition
DTC is set when command from PCM to immobilizer unit exceeds limit or there is no response from immobilizer unit. Possible causes are:
- Open or short circuit.
- Immobilizer unit malfunction.
- Immobilizer component malfunction.