Positive Crankcase Ventilation
- Check PCV Valve
Remove PCV valve. Shake valve and listen for rattle. If PCV valve rattles when shaken, go to next step. Replace PCV valve if it does not rattle when shaken.
- Check PCV System
Start engine and warm to normal operating temperature. Disconnect hose from remote air cleaner or outlet tube. Place a stiff piece of paper over end of hose. If vacuum from hose does not hold paper in place for one minute, repair clogged or leaking hose as necessary. If vacuum from hose holds paper in place for one minute, PCV system is okay and testing is complete.