On-Vehicle Tests: Notes
CAUTION:
To avoid damage to the internal parts (power transistor) of the generator, do NOT apply direct battery positive voltage to the generator terminal "D".
NOTE:
Prior to performing generator testing, turn OFF all electrical components. Place transmission in Neutral and apply parking brake.