LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mazda >> 2002 >> Protege5 Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Self-Diagnostics >> Diagnostic Tests >> DTC P0401: EGR System, Insufficient Flow >> Condition
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P0401: EGR System, Insufficient Flow: Condition

DTC is set when the difference in intake manifold pressure between open EGR and closed EGR is too small. This is an intermittent monitor. MIL is illuminated when PCM detects malfunction during 2 consecutive drive cycles. Possible causes are: