Reprogram error recovery procedure for both immobilizer unit and PCM replacement

NOTE:
  • If no specific time interval is given, each step should be performed within 30 seconds  of the previous step.
  1. Using key 1, start engine. After security light illuminates for 1-2 seconds,  turn key 1 to LOCK position.
  2. Using key 1, turn ignition switch to ON position then back to LOCK position five times.  Key should not remain at ON position or LOCK position for more than 1 second. 
  3. Using key 1, turn ignition switch to ON position (security light illuminates).
  4. Turn key 1 to LOCK position and remove from steering lock (security light goes out).
  5. Using key 2, start engine. Observe that security light illuminates (for 1-2 seconds  ) and engine continues to run.
  6. Turn key 2 to LOCK position and remove from steering lock.
  7. Repeat Steps 5 and 6 with key 1.
  8. Repeat Steps 5 and 6 with key 3.
  9. If there are 4-8 keys (valid and/or new keys), repeat Steps 5 and 6.
  10. Wait for 30 seconds  to quit reprogram mode.
  11. After reprogramming, clear DTCs of PCM with WDS or equivalent.