Immobilizer Unit Inspection: Notes
- Measure the voltage at the immobilizer unit terminals as indicated below.
- Disconnect the immobilizer unit connector before inspecting for continuity at terminal C.
- If not as specified, inspect the parts listed under "Action".
- If the parts and wiring harnesses are okay but the system still does not work properly, replace the immobilizer unit.