Selector Cable Adjustment
- Remove the column cover.
- Shift the selector lever to P position.
- Loosen nut A shown in Fig 1 .
- Pull the selector lever to the R position side gate of P position, and tighten nut A.
Tightening torque
16-22 N.m {1.6-2.3 kgf.m, 12-16 ft.lbf}
- Verify that the selector lever bolt end is exposed from the nut.
- Install the column cover.