Detection Condition
DTC is set when PCM detects TP sensor voltage at PCM 31-pin harness connector terminal "4V" is more than 4.8 volts after engine start. PCM determines that TP circuit has a malfunction. This is a Continuous Monitor (CM). MIL illuminates if PCM detects malfunction conditions in 2 consecutive drive cycles. Pending code is not available. Freeze Frame Data is available and DTC is stored in PCM memory.