PCM Inspection Using the SST (104 Pin Breakout Box): Notes
- Disconnect the negative battery cable.
- Disconnect the PCM connector.
- Connect the SST (104 Pin Breakout Box) to the PCM as shown.
- Tighten the connector attaching bolt.
Tightening torque
3.0-5.4 N.m {30-56 kgf.cm, 27-48 in.lbf}
- Connect the negative battery cable.
- Measure the voltage at each terminal.
- If any incorrect voltage is detected, inspect the related systems, wiring harnesses and connectors referring to the Action column in the terminal voltage table.