Open circuit
- If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
- MAF/IAT sensor terminal A and main relay terminal C
- MAF/IAT sensor terminal B and PCM terminal 5U
- MAF/IAT sensor terminal C and PCM terminal 5N