Metering Oil Pump Switch Inspection
>>
Circuit Open/Short Inspection
>>
Short circuit
April 5, 2026:
LEMON Manuals is launched!
Read the announcement.
Short circuit
If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
Metering oil pump switch terminal A and body ground
Metering oil pump switch terminal A and power supply