Fuel Pump Operation Inspection: Specification
B+ (Ignition switch at on)
- If the voltage is as specified, inspect the following:
- Fuel pump continuity
- Fuel pump GND
- Wiring harness between fuel pump relay and PCM terminal 1AR (with immobilizer system), 1AQ (without immobilizer system)
- If not as specified, inspect the following:
- Fuel pump relay
- Wiring harness connector (Main relay - fuel pump relay - fuel pump.)