DTC P0480 DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME PID DATA on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to available repair information.
|
| No | Go to the next step. | ||
| 3 | VERIFY CURRENT INPUT SIGNAL STATUS-IS CONCERN INTERMITTENT OR CONSTANT
|
Yes | Go to intermittent concern troubleshooting procedure. (See INTERMITTENT CONCERN TROUBLESHOOTING .) |
| No | Go to the next step. | ||
| 4 | INSPECT VSS CONNECTOR FOR POOR CONNECTION
|
Yes | Go to the next step. |
| No | Reconnect the connector, then go to Step 11. | ||
| 5 | INSPECT THE VSS
|
Yes | Go to the next step. |
| No | Replace VSS, then go to Step 11. | ||
| 6 | INSPECT VSS CIRCUIT FOR SHORT TO POWER
|
Yes | Repair or replace suspected harness, then go to Step 11. |
| No | Go to the next step. | ||
| 7 | INSPECT VSS CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace suspected harness, then go to Step 11. |
| No | Go to the next step. | ||
| 8 | INSPECT VSS CIRCUITS FOR SHORTS
|
Yes | Repair or replace suspected harness, then go to Step 11. |
| No | Go to the next step. | ||
| 9 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair terminal, then go to Step 11. |
| No | Go to the next step. | ||
| 10 | INSPECT VSS CIRCUIT FOR OPEN CIRCUIT
|
Yes | Inspect VSS pulse wheel for damage. Replace VSS pulse wheel and go to the next step. |
| No | Repair or replace suspected harness, then go to the next step. | ||
| 11 | VERIFY TROUBLESHOOTING OF DTC P0500 COMPLETED
|
Yes | Replace PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 12 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to applicable DTC troubleshooting. (See DTC TABLE ) |
| No | Troubleshooting completed. | ||