Remote Keyless Entry Transmitter Out Of Synchronization
NOTE:
- All remote transmitters must be present to begin diagnosis of the remote keyless entry (RKE) system.
SYMPTOM TROUBLESHOOTING CHART - REMOTE KEYLESS ENTRY TRANSMITTER OUT OF SYNCHRONIZATION
| PINPOINT TEST 5 | REMOTE KEYLESS ENTRY TRANSMITTER OUT OF SYNCHRONIZATION | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | RESYNCHRONIZE THE INOPERATIVE REMOTE TRANSMITTER
|
Yes | The system is OK. Clear the DTCs. Test the system for normal operation. |
| No | Go to step 2. | ||
| 2 | CHECK FOR A SECOND REMOTE TRANSMITTER
|
Yes | Go to step 3. |
| No | Go to step 4. | ||
| 3 | RESYNCHRONIZE THE INOPERATIVE KEYLESS ENTRY REMOTE TRANSMITTER USING THE SECOND KEYLESS ENTRY REMOTE TRANSMITTER
|
Yes | The system is OK. Clear the DTCs. Test the system for normal operation. |
| No | Go to step 4. | ||
| 4 | PROGRAM THE INOPERATIVE KEYLESS ENTRY REMOTE TRANSMITTER
|
Yes | The system is OK. INFORM the customer that any remote transmitters not present will need to be reprogrammed. Clear the DTCs. Test the system for normal operation. |
| No | See DOORS DO NOT LOCK/UNLOCK USING THE REMOTE TRANSMITTER . | ||