Mass Air Flow/Intake Air Temperature (MAF/IAT) Sensor Removal/Installation
CAUTION:
- Sensing elements located in the airflow bypass are not to be tampered with.
- Disconnect negative battery cable.
- Disconnect the mass air flow (MAF) sensor electrical connector.
- Disconnect the air cleaner outlet tube from the MAF sensor.
- Remove the four bolts and the MAF sensor.
CAUTION:
- Do not tamper with the MAF sensing elements located in the airflow bypass. Tampering may result in failure.
NOTE:- The MAF sensor module and body are calibrated and installed as a unit.
- To install, reverse the removal procedure.
Tightening torque
4-5 N.m { 41-51 kgf.cm, 38-44 in.lbf }