DTC P0117 - DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED 
  • Have FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS (Engine cooling system related) been recorded?
Yes Go to the next step.
No Record FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS on repair order, then go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Check for related Service Bulletins and/or on-line repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
3 VERIFY CURRENT INPUT SIGNAL STATUS-IS CONCERN INTERMITTENT OR CONSTANT  YES Go to the next step.
No Intermittent concern exists. Go to INTERMITTENT CONCERNS TROUBLESHOOTING procedure.

(See INTERMITTENT CONCERN TROUBLESHOOTING .)

4 INSPECT TERMINAL BENT 
  • Turn the ignition switch off.
  • Disconnect ECT sensor connector.
  • Check for bent of ECT sensor terminals A and B (part-side).
  • Is there any malfunction?
Yes Repair or replace the terminal, then go to Step 8.
No Go to the next step.
5 CLASSIFY ECT SENSOR MALFUNCTION OR HARNESS MALFUNCTION 
  • Disconnect ECT sensor connector.
  • Turn key to ON (Engine off).
  • Measure voltage at breakout box terminal 41.
  • Is voltage below 0.14 V? 
Yes Go to the next step.
No Replace ECT sensor, then go to Step 8.
6 INSPECT ECT SIGNAL CIRCUIT FOR SHORT TO GROUND 
  • Turn the ignition switch off.
  • Disconnect PCM connector.
  • Check continuity between ECT sensor terminal A (harness-side) and body ground.
  • Is there continuity?
Yes Repair or replace harness for short to ground, then go to Step 8.
No Go to the next step.
7 INSPECT IAT CIRCUIT FOR SHORT HARNESSES 
  • Check continuity between ECT sensor terminal A and B (harness-side).
  • Is there continuity?
Yes Repair or replace harness for short, then go to the next step.
No Go to the next step.
8 VERIFY TROUBLESHOOTING OF DTC P0117 COMPLETED 
  • Make sure to reconnect all disconnected connectors.
  • Clear the DTC from the PCM memory using the WDS or equivalent.
  • Start turn key to ON (Engine off).
  • Is same DTC present?
Yes Replace PCM, then go to the next step.
No Go to the next step.
9 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE .)
No Troubleshooting completed.