Diagnostic procedure
DTC P0117 - DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | VERIFY CURRENT INPUT SIGNAL STATUS-IS CONCERN INTERMITTENT OR CONSTANT
|
YES | Go to the next step. |
| No | Intermittent concern exists. Go to INTERMITTENT CONCERNS TROUBLESHOOTING procedure. | ||
| 4 | INSPECT TERMINAL BENT
|
Yes | Repair or replace the terminal, then go to Step 8. |
| No | Go to the next step. | ||
| 5 | CLASSIFY ECT SENSOR MALFUNCTION OR HARNESS MALFUNCTION
|
Yes | Go to the next step. |
| No | Replace ECT sensor, then go to Step 8. | ||
| 6 | INSPECT ECT SIGNAL CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace harness for short to ground, then go to Step 8. |
| No | Go to the next step. | ||
| 7 | INSPECT IAT CIRCUIT FOR SHORT HARNESSES
|
Yes | Repair or replace harness for short, then go to the next step. |
| No | Go to the next step. | ||
| 8 | VERIFY TROUBLESHOOTING OF DTC P0117 COMPLETED
|
Yes | Replace PCM, then go to the next step. |
| No | Go to the next step. | ||
| 9 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||