Diagnostic procedure
DTC P2507 - DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | INSPECT EEC FUSE
|
Yes | Go to step 5. |
| No |
|
||
| 4 | INSPECT MONITOR CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace harness for short to ground and install new fuse, then go to Step 7. |
| No | Go to step 7. | ||
| 5 | INSPECT POOR CONNECTION OF PCM CONNECTOR
|
Yes | Repair terminals, then go to Step 7. |
| No | Go to the next step. | ||
| 6 | INSPECT MONITOR CIRCUIT FOR OPEN
|
Yes | Go to the next step. |
| No | Repair or replace harness for open, then go to the next step. | ||
| 7 | VERIFY TROUBLESHOOTING OF DTC P2507 COMPLETED
|
Yes | Replace PCM, then go to the next step. |
| No | Go to the next step. | ||
| 8 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||