Diagnostic procedure
DTC P0125 - DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA AND DIAGNOSTIC MONITORING TEST RESULTS HAVE BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA and DIAGNOSTIC MONITORING TEST RESULTS on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | VERIFY CURRENT INPUT SIGNAL STATUS-IS CONCERN INTERMITTENT OR CONSTANT
|
Yes | Intermittent concern exists. Go to INTERMITTENT CONCERNS TROUBLESHOOTING procedure. |
| No | Go to the next step. | ||
| 4 | INSPECT POOR CONNECTION OF ECT SENSOR CONNECTOR
|
Yes | Repair or replace the terminal, then go to Step 7. |
| No | Go to the next step. | ||
| 5 | INSPECT ECT SENSOR
|
Yes | Go to the next step. |
| No | Replace ECT sensor, then go to Step 7. | ||
| 6 | INSPECT POOR CONNECTION OF PCM CONNECTOR
|
Yes | Repair or replace the terminal, then go to the next step. |
| No | Go to the next step. | ||
| 7 | VERIFY TROUBLESHOOTING OF DTC P0125 COMPLETED
|
Yes | Replace PCM, then go to the next step. |
| NO | Go to the next step | ||
| 8 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .). |
| No | Troubleshooting completed. | ||