Diagnostic procedure
DTC P0446 - DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record FREEZE FRAME DATA on repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnostic according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | CHECK EVAP SYSTEM LEAK DETECTION PUMP CIRCUIT FOR SHORT TO POWER
|
Yes | Repair or replace wiring harness, then go to Step 5. |
| No | Go to the next step. | ||
| 4 | INSPECT COV (EVAP SYSTEM LEAK DETECTION PUMP)
|
Yes | Go to the next step. |
| No | Replace EVAP system leak detection pump, then go to the next step. | ||
| 5 | VERIFY TROUBLESHOOTING OF DTC P0446 COMPLETED
|
Yes | Replace PCM, then go to the next step. |
| No | Go to the next step. | ||
| 6 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||