DTC P2503 - DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY FREEZE FRAME DATA HAS BEEN RECORDED 
  • Has FREEZE FRAME DATA been recorded?
Yes Go to the next step.
No Record FREEZE FRAME DATA on repair order, then go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Check for related Service Bulletins and/or online repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, go to the next step.
No Go to the next step.
3 INSPECT DRIVE BELT CONDITION 
  • Verify that drive belt auto tensioner indicator mark in not exceeding limit.

    (See DRIVE BELT INSPECTION .)

  • Is front drive belt okay?
Yes Go to the next step.
No Replace or adjust drive belt, then go to Step 9.
4 INSPECT GENERATOR CONNECTOR FOR POOR CONNECTION 
  • Turn the ignition switch off.
  • Disconnect generator connector.
  • Check for poor connection (damaged, pulled-out pins, corrosion, etc.).
  • Is there any malfunction?
Yes Repair or replace the terminal, then go to Step 9.
No Go to the next step.
5 INSPECT GENERATOR CIRCUIT FOR SHORT TO GND 
  • Turn the ignition switch off.
  • Check continuity between the following circuits:
    • Generator terminal D (harness-side) and body GND
    • Generator terminal P (harness-side) and body GND
  • Is there continuity?
Yes Repair or replace harness for short to GND, then go to Step 9.
No Go to the next step.
6 INSPECT GENERATOR  Yes Replace generator, then go to Step 9.
(See GENERATOR REMOVAL/INSTALLATION .)
No Go to the next step.
7 INSPECT PCM CONNECTOR FOR POOR CONNECTION 
  • Turn the ignition switch off.
  • Disconnect PCM connector.
  • Check for poor connection (such as damaged, pulled-out pins, and corrosion).
  • Is there any malfunction?
Yes Repair or replace the terminal, then go to Step 9.
No Go to the next step.
8 INSPECT GENERATOR CIRCUIT FOR OPEN CIRCUIT 
  • Turn the ignition switch off.
  • Check continuity between the following circuits:
    • Generator terminal D (harness-side) and PCM terminal 36 (harness-side)
    • Generator terminal P (harness-side) and PCM terminal 63 (harness-side)
  • Is there continuity?
Yes Go to the next step.
No Repair or replace harness for open circuit, then go to the next step.
9 VERIFY TROUBLESHOOTING OF DTC P2503 COMPLETED 
  • Make sure to reconnect all disconnected connectors.
  • Clear the DTC from the memory using the WDS or equivalent.
  • Turn ignition switch to OFF, then start engine.
  • Is same DTC present?
Yes Replace PCM, then go to the next step.
(See PCM REMOVAL/INSTALLATION .)
No Go to the next step.
10 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE .)
No Troubleshooting completed.