Wastegate Control System Operation Inspection
If simulation function of WDS or equivalent is used:
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve-PCM terminal 4H)
- Wastegate control solenoid valve (Stuck open)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Connect the WDS or equivalent to the DLC-2 and verify that DTC P0245 or P0246 are shown. Perform the DTC inspection.
(See DTC P0245 ).
(See DTC P0246 ).
- Select the VGT PID.
- Increase the duty value of the wastegate control solenoid valve and inspect if the operation sound of the solenoid valve is heard.
- If the operation sound is heard, inspect for loose or damaged vacuum hoses. (Wastegate actuator - wastegate control solenoid valve - intake hose)
- If the operation sound is not heard, perform the wastegate control solenoid valve inspection. (See WASTEGATE CONTROL SOLENOID VALVE INSPECTION ).
- Warm up the engine to normal operating temperature.
- Monitor the VGT and APP PIDs using the WDS or equivalent.
- Run the engine with the APP PID above 30%
and verify that the VGT PID value increases from 0%.
- If the VGT PID is 0% , inspect the APP PID.
If simulation function of WDS or equivalent is not used:
- Start the engine and run it is idling.
- Disconnect the hose between the wastegate control solenoid valve and the intake pipe.
- Put a finger to the wastegate control solenoid valve and verify that there is no pressure applied.
- If there is pressure, inspect the following:
- Wiring harness and connectors (Wastegate control solenoid valve - PCM terminal 4H)
- Wastegate control solenoid valve (Stuck open)
- If there is pressure, inspect the following:
- Warm up the engine to normal operating temperature.
- Connect the WDS or equivalent to the DLC-2 and verify that the DTC P0245 or P0246 are shown. Perform the DTC inspection.
(See DTC P0245 ).
(See DTC P0246 ).
- Warm up the engine to normal operating temperature.
- Monitor the VGT and APP PIDs using the WDS or equivalent.
- The hose between the wastegate control solenoid valve and intake pipe is disconnected.
- Run the engine with the APP PID above 30%
and verify that the VGT PID value increases from 0% and there is pressure applied.
- If the VGT PID is 0% , inspect the TP_REL PID.
- If there is no pressure applied, inspect for the following:
- Wastegate control solenoid valve (Stuck closed)
- Hose connection (Intake hose (turbocharger compressor downstream side) - wastegate actuator - intake hose (turbocharger compressor upstream side))