Generator Inspection [AJ]: Generator: Current
- Verify that the battery is fully charged.
- Charge if necessary.
- Verify that the drive belt deflection/tension is correct. (See
DRIVE BELT INSPECTION [AJ]
.)
- Replace if necessary.
- Disconnect the negative battery cable.
- Connect an ammeter, capable of reading 120 A or above, between generator terminal B and the wiring harness.
- Connect the negative battery cable.
- Turn off all electrical loads.
- Start the engine and increase the engine speed to 2,000-2,500 rpm.
- Turn the following electrical loads on and verify that the current reading increases.
- Headlights
- Blower motor
- Rear window defroster
- If generator terminal B current will not increase, repair or replace the generator as necessary.
NOTE:- Current required for generating power varies with electrical loads applied.
Measuring conditions
Room temperature: 20 °C {68 °F}
Voltage: 13.5 V Engine hot
STANDARD CURRENT (REFERENCE)
| Engine speed (rpm) | Terminal B current (A) | ||
|---|---|---|---|
| 1,000 | 0(1)-90 | ||
| 2,000 | 0(1)-105 | ||
|
|||