Continuity Inspection
- Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION .) (See NEUTRAL SWITCH REMOVAL/INSTALLATION .)
- Verify that the continuity between neutral switch terminals 1A and 2A is as indicated in Fig 1
.
- If not as indicated in Fig 1 , replace the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION .) (See NEUTRAL SWITCH REMOVAL/INSTALLATION .)
- If the monitor item condition/specification (reference) is not within the specification, even though there is no malfunction, perform the CIRCUIT OPEN/SHORT INSPECTION .