Diagnostic Procedure
DTC P2507 DIAGNOSTIC PROCEDURE TABLE
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record the FREEZE FRAME DATA on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | INSPECT MONITOR CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for short to ground and install new fuse, then go to Step 6. |
| No | Go to the next step. | ||
| 4 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair the terminals, then go to Step 6. |
| No | Go to the next step. | ||
| 5 | INSPECT MONITOR CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for an open circuit, then go to the next step. | ||
| 6 | VERIFY TROUBLESHOOTING OF DTC P2507 COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 7 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
| No | Troubleshooting completed. | ||