Using M-MDS
- Connect the M-MDS to the DLC-2.
- Using the simulation function "FP", start the fuel pump. (See ON-BOARD DIAGNOSTIC TEST .)
- Verify that there is no fuel leakage from the pressurized parts.
Standard
- There shall be no leakage after 5 min.
- In the case of fuel leakage, replace the following components and then do the recheck by the fuel leakage checking procedure.
- If there is leakage, replace the fuel hoses and clips.
- If there is damage on the seal on the fuel pipe side, replace the fuel pipe.