Diagnostic Procedure
NO. 16 HIGH OIL CONSUMPTION/LEAKAGE DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | RESULTS | ACTION |
|---|---|---|---|
| 1 | INSPECT ENGINE OIL AND RELATED PARTS CONDITION
|
Yes | Repair or replace the malfunctioning part according to the inspection results. Repeat Step 1. |
| No | Go to the next step. | ||
| 2 | INSPECT IF MALFUNCTION CAUSE IS PCV VALVE OR OTHER
|
Yes | Replace the PCV valve and the oil separator as a single unit, then go to the next step. (See POSITIVE CRANKCASE VENTILATION (PCV) VALVE REMOVAL/INSTALLATION .) |
| No | Inspect the internal engine parts such as valves, valve guides, valve stem seals, cylinder head drain passage, and piston rings. Repair or replace the malfunctioning part according to the inspection results. |
||
| 3 | Verify test results.
|
||