Variable Tumble Shutter Valve Position Sensor Inspection
NOTE:
- The variable tumble shutter valve position sensor cannot be removed as a single unit. When replacing the variable tumble shutter valve position sensor, replace it together with the intake manifold as a single unit.
- Connect the M-MDS to the DLC-2.
- Switch the ignition to ON.
- Verify that the variable tumble shutter valve position sensor output voltage (PID: IMRC_POS) within the specification. (See ON-BOARD DIAGNOSTIC TEST
.) (See PCM INSPECTION .)
- If not as specified, replace the intake manifold. (See INTAKE-AIR SYSTEM REMOVAL/INSTALLATION .)